Mode No.
1
(Class 1, 2, and 3)
104
25 Process Speed
[Fusing Temperature]
105
( H eating or P ressure roller: Paper Type, [Color], S implex/ D uplex, Process Speed)
Paper Type -> N: Normal, OHP. TH: Thick, SP: Special
Some settings of fusing temperature depend on the destination (US or Europe/Asia).
US: Setting for US, EU: Setting for Europe/Asia
1
H: Ready
2
P: Ready
The following SPs set the target operating temperatures of the heating and pressure
rollers in various modes. (The default settings are different for N. America and Eur./Asia)
4
H:N [K] S 125
5
H:N [K] S 185
6
H:N [K] D 125
7
H:N [K] D 185
8
H:N[FC] S 62.5
9
H:N[FC] S 125
10 H:N[FC] D 62.5
SM
Function / [ Setting ]
*
Selects the power-on default target fusing
BCU
operation temperature.
The target operating fusing temperature depends
on the process speed. When the machine is
switched on, it starts warming up for the process
speed specified in this SP mode.
[0 to 4 / 4 / 1/step] Alphanumeric
0: CL (Color) 62.5 mm/s (temperature specified by
SP 1-105-8 and 19)
1: CL (Color) 125 mm/s (temperature specified by
SP 1-105-9 and 20)
2: OHP / Thick (temperature specified by SP 1-
105-13 and 28)
3: B&W 125 mm/s (temperature specified by SP 1-
105-4 and 15)
4: B&W 185 mm/s (temperature specified by SP 1-
105-5 and 16)
*
Sets the heating roller temperature for the printing
BCU
ready condition.
After the main switch has been turned on, the
machine enters the print ready condition when the
heating roller temperature reaches the
temperature specified in this SP mode.
When the machine is in the recovery mode from
the energy saver or auto off mode, the machine
becomes ready when both heating and pressure
roller temperatures reach the specified
temperature.
Ready temperature = (Target temperature
specified in SP1-104-25 or 105-3 to 28) –
Temperature specified in this SP mode.
[ 10 to 100 / 10 / 1
Sets the pressure roller temperature for the
printing ready condition.
Ready temperature = (Target temperature
specified in SP1-104-25 or 105-3 to 28) –
Temperature specified in this SP mode
NA: [ 10 to 100 / 10 / 1
EU: [ 10 to 100 / 20 / 1
*
[ 100 to 190 / 175 / 5°C/step]
BCU
[ 100 to 190 / NA: 185 EU: 180 / 5°C/step]
[ 100 to 190 / 165 / 5°C/step]
[ 100 to 190 / 175 / 5°C/step]
[ 100 to 190 / 150 / 5°C/step]
[ 100 to 190 / NA: 175 EU: 180 / 5°C/step]
[ 100 to 190 / 145 / 5°C/step]
5-11
COPY SP MODE
o
C/step ]
o
C/step ]
o
C/step ]
G570