SP3-XXX (Process)

Mode No.
3
(Class 1, 2, and 3)
[TD Initial] TD Sensor Initialization ([Color])
005
1
[K]
2
[Y]
3
[M]
4
[C]
5
[All Color]
6
Result
006
[Vcnt Initial] Vcnt Initial Setting Display ([Color])
1
[K]
2
[Y]
3
[M]
4
[C]
[Vcnt Current] Vcnt Current Value Display ([Color])
007
1
[K]
2
[Y]
3
[M]
4
[C]
[Humidity]
008
1
Humidity
[Vsg Display] Vsg Display (Front or Rear)
107
1
Vsg F
2
LED Current F
3
Vsg R
4
LED Current R
SM
PRINTER ENGINE SERVICE MODE
Function / [ Setting ]
Initializes the developer. DFU
Press the Enter key to execute the initialization
after the machine asks "Execute?".
Displays the developer initialization result.
[ 1 to 9 / - / - ]
1: Success
2 to 9: Failure
All colors are displayed. Values is displayed in the
order K Y C M.
e.g., 1 1 2 1: Initialization of Cyan failed but the
others succeeded
See the troubleshooting section for details.
Displays the initial Vcnt value.
[ 0 to 240 / 100 / 0.1/step ]
Displays the current Vcnt value.
[ 0 to 240 / - / 0.1/step ]
Displays the humidity measured by the
humidity/temperature sensor.
[ 0 to 100 / - / 1/step ]
*
Displays the Vsg value of the front ID sensor.
[ 0.00 to 5.00 / - / 0.01V/step ]
Vsg is normally 4.0 ± 0.5 V.
If Vsg is out of the adjustment range and this is
detected 3 times consecutively, it leads to SC385.
*
Displays the ID sensor LED current adjusted
during Vsg adjustment.
[ 0 to 1023 / - / 1 ]
*
Displays the Vsg value of the rear ID sensor.
[ 0.00 to 5.00 / - / 0.01V/step ]
Vsg is normally 4.0 ± 0.5 V.
If Vsg is out of the adjustment range and this is
detected 3 times consecutively, it leads to SC385.
*
Displays the ID sensor LED current adjusted
during Vsg adjustment.
[ 0 to 1023 / - / 1 ]
5-23
G060