MACHINE INSTALLATION
4. With the 2 square holes [A] in the table
board in front of you as shown, attach the
left [B] and right [C] arms. When attaching
the right arm, secure the ground wires [D]
with screws [E] as shown.
NOTE: Make sure the square holes in the
table board is facing you during
this procedure.
5. Set the table board [F] on the stand as
shown.
NOTE: 1) Please make sure that the
screw holes for the scanner
unit are positioned at the
right rear and left front of the
table board.
2) Recommended attachment
positions for the table board:
• Machine with Two-tray
Paper Supply Unit & LCT:
2nd hole from the top
• Machine with One-tray
Paper Supply Unit: 6th
hole from the top
3) When attaching the table board at a lower position than the
recommended one, make sure the upper right cover can be opened
and toner cartridges (especially black) can be replaced.
When attaching the table board below the recommended position, it
is necessary to shift the printer mainframe 10 cm (3.9") toward the
front so that the upper right cover can be opened for toner
replenishment.
6. Secure the two grounding wires [G]
( x 2 each). There is a wire at the left side
and one at the right side.
7. Attach the securing brackets [H] to the left
and right arms as shown (1 thumb screw [I]
for each).
G570
[B]
[A]
[F]
1-10
[E]
[D]
[G]
G570I104.WMF
[H]
[I]
[C]
G570I103.WMF
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

G570G082