Gestetner G060 Service Manual page 556

Table of Contents

Advertisement

COPY SP MODE
2
(Class 1, 2, and 3)
103
LD Power Control for CF ([Color Mode, Color]
101
CF:[K,K] 1
102
CF:[K,K] 2
103
CF[FC,K]
104
CF:[FC:Y]
105
CF:[FC,M]
106
CF:[FC,C]
107
CF:[K] OHP/TH
108
CF:[Y] OHP/TH
109
CF:[M] OHP/TH
110
CF:[C] OHP/TH
109
[LD Beam Pitch] LD Beam Pitch
Sets the beam pitch for black in 1200 dpi or 600 dpi mode.
NOTE: After replacing the laser optics housing unit, the data printed on the decal attached
to the new unit must be input with this SP mode.
2
Pitch 1200
3
Pitch 600
5
Display 1200
6
Display 600
112
[Polygon OFF Timing 1] Polygon Mirror Motor OFF Timing 1
1
Warming-up
2
Job End
[Polygon OFF Timing 2] Polygon Mirror Motor OFF 2
113
1
Polygon OFF Timing 2
201
[Development Bias] ([Color], Process Speed)
1
[K] 62.5
2
[K] 125
3
[K] 185
4
[Y] 62.5
5
[Y] 125
6
[M] 62.5
7
[M] 125
8
[C] 62.5
9
[C] 125
G570
Mode No.
*
BCU
*
BCU
*
BCU
*
BCU
Function / [ Setting ]
[ 0 to 1023 / 604 / 1/step ] DFU
[ 0 to 1023 / 604 / 1/step ] DFU
[ 0 to 1023 / 720 / 1/step ] DFU
[ 0 to 1023 / 720 / 1/step ] DFU
[ 0 to 1023 / 720 / 1/step ] DFU
[ 0 to 1023 / 720 / 1/step ] DFU
[ 0 to 1023 / 590 / 1/step ] DFU
[ 0 to 1023 / 590 / 1/step ] DFU
[ 0 to 1023 / 590 / 1/step ] DFU
[ 0 to 1023 / 590 / 1/step ] DFU
[ 0 to 255 / 50 / 50 pulse/step ] FA
[ 0 to 255 / 42 / 50 pulse/step ] FA
[ 0 to 255 / - / 1 pulse/step ]
[ 0 to 255 / - / 1 pulse/step ]
The polygon mirror motor turns off if the machine
receives no print start command for the time
specified in this SP mode after receiving the print
preparation command.
[ 0 to 60 / 10 / 1 second/step ]
0: Not turned off except for Energy Saver mode
The polygon mirror motor turns off if the machine
receives no print job for the time specified in this
SP mode after the previous job was completed.
[ 0 to 60 / 1 / 1 second/step ]
0: Not turned off except for Energy Saver mode
The polygon mirror motor does not turn on until
the printer enters the ready condition even after
receiving the print start command.
[ 0 or 1 / 1 / 1 /step ]
0: Enable, 1: Disable
NOTE: When a user complains about high
frequency noise, enabling this mode can
minimize the noise.
Adjusts the development bias.
Development bias is automatically adjusted during
process control; therefore, adjusting these settings
has no effect while Process Control (SP3-125
Default: ON) is activated.
After deactivating Process Control with SP3-125,
the values in these SP modes are used for
printing.
[ 200 to 800 / 500 / 10 V/step ] DFU