Gestetner G060 Service Manual page 183

Table of Contents

Advertisement

Mode No.
2
(Class 1, 2, and 3)
[Polygon OFF 1] Polygon Mirror Motor OFF Timing
112
1
Warming-up
2
Job End
113
[Polygon OFF 2] Polygon Mirror Motor OFF
1
Polygon OFF 2
201
[Dev. Bias] Development Bias ([Color], Process Speed)
1
[K] 62.5
2
[K] 125
3
[K] 185
4
[Y] 62.5
5
[Y] 125
6
[M] 62.5
7
[M] 125
8
[C] 62.5
9
[C] 125
[Forced Toner] Forced Toner Supply ([Color])
207
1
[K]
2
[Y]
3
[M]
4
[C]
208
[Toner Mode] Toner Supply Method ([Color])
1
[K]
2
[Y]
3
[M]
4
[C]
5
Fixed Rate [K]
6
Fixed Rate [Y]
7
Fixed Rate [M]
8
Fixed Rate [C]
SM
PRINTER ENGINE SERVICE MODE
Function / [ Setting ]
*
The polygon mirror motor turns off if the machine
receives no print start command for the time
specified in this SP mode after receiving the print
preparation command.
[ 0 to 60 / 10 / 1 second/step ]
0: Not turned off except for Energy Saver mode
*
The polygon mirror motor turns off if the machine
receives no print job for the time specified in this
SP mode after the previous job was completed.
[ 0 to 60 / 1 / 1 second/step ]
0: Not turned off except for Energy Saver mode
The polygon mirror motor does not turn on until
the printer enters the ready condition even after
receiving the print start command.
[ 0 or 1 / 1 / 1 /step ]
0: Enable, 1: Disable
NOTE: When a user complains about high
frequency noise, enabling this mode can
minimize the noise.
*
Adjusts the development bias.
Development bias is automatically adjusted during
*
process control; therefore, adjusting these settings
*
has no effect while Process Control (SP3-125
*
Default: ON) is activated.
*
After deactivating Process Control with SP3-125,
*
the values in these SP modes are used for
*
printing.
*
[ 200 to 800 / 500 / 10 V/step ] DFU
*
*
Forces toner to be supplied to the development
unit for the number of times specified by this SP
*
mode.
*
1 time: The toner supply clutch turns on for 0.7 s
*
and off for 1.3 s.
[ 0 to 3 / 2 / 1/step ]
*
Selects the toner supply method.
[ 0 to 2 / 1 / 1/step ] Alphanumeric
*
0: Fixed supply (with the supply rates stored with
*
SP2-208-5 to 8)
*
1: Fuzzy control supply
2: Proportional control supply (using the Vref
values stored with SP2-224-5 to 8)
*
Sets the toner supply rate used when the toner
supply method (SP2-208-1 to 4) is set to '0' (fixed
*
supply mode).
*
[ 0 to 100 / 5 / 1%/step ]
*
5-15
G060

Advertisement

Table of Contents
loading

This manual is also suitable for:

G570G082

Table of Contents