Mode No.
2
(Class 1, 2, and 3)
[TD Vcnt Control] TD Sensor Vcnt Control
223
1
Initialization
2
Humidity
3
Toner Fill Up
[Vcnt / Vref] Vcnt / Vref ([Color])
224
Adjusts the Vcnt value manually.
The value in this SP mode is effective until after the next process control self-check. To
always use this value for some reason, select proportional control supply mode with SP2-
208-1 to 4.
1
Vcnt [K]
2
Vcnt [Y]
3
Vcnt [M]
4
Vcnt [C]
Adjusts the Vref value manually.
The value in this SP mode is effective until the next process control self-check. To always
use this value for some reason, select proportional control supply mode with SP2-208-1 to
4.
5
Vref [K]
6
Vref [Y]
7
Vref [M]
8
Vref [C]
SM
Function / [ Setting ]
*
Enables or disables the Vcnt Auto Adjustment
BCU
when detecting a new development unit.
When the machine detects a new development
unit, developer initialization automatically starts.
During the developer initialization, Vcnt is
automatically adjusted so that Vt is within 3.0 ±
0.1V.
[ 0 or 1 / 1 / - ] Alphanumeric, DFU
0: Disabled
1: Enabled
Enables or disables the Humidity Auto Correction.
This corrects the Vcnt value for the current
humidity. This correction is applied to both the
Vcnt values automatically adjusted during
developer initialization and manually adjusted with
SP2-224-1 to 4.
If this correction does not work well under certain
environmental conditions or due to a defective
humidity sensor, deactivate the Humidity Auto
Correction and adjust the Vcnt value in SP2-224-1
to 4 (by trial and error).
[ 0 or 1 / 1 / - ] Alphanumeric
0: Disabled
1: Enabled
Activates or deactivates the Toner Fill Up mode,
which fills up the toner supply tube with toner
during developer initialization.
This function is required only at machine
installation. Although the default is "0", the factory
setting is "1". After toner fill-up occurs during
machine installation, the setting is changed to "0"
automatically.
[ 0 or 1 / 0 / - ] Alphanumeric, DFU
0: Deactivate
1: Activate
*
[ 0 to 220 / 100 / 0.1 V/step ]
NOTE: The main switch must be turned off and on
BCU
#
to effect the setting change.
*
[ 0 to 50 / 28 / 0.1 V/step ]
BCU
5-21
COPY SP MODE