Rev. 10/2002
DESCRIPTION OF MODIFICATION
Continued From Pervious Page
The New Coverage Counters will only
!
display the value of 999.99 and will not
function. The Coverage Counter
[7-833-05 to 08] provides image coverage
calculations for when Meter Charge Mode
(SP9-930 set to 0) is set to "OFF." Use the
Coverage Counter [SP7-833-05 to 08] if
Meter Charge Mode (SP9-930 set to 0) is
set to "OFF." Use the New Coverage
Counter [SP7-908-01 to 08] when Meter
Charge Mode (SP9-930 set to 1) is set to
"ON." SP7-908-5 to 8 displays the same
data as SP7-833-11 to -14.
The machine automatically detects
!
whether a 4kB or 8kB NVRAM is installed
on the BCU board.
A grid pattern has been added to SP mode
!
copy images. To activate this, it is
necessary to use system firmware ver1.07
or newer (for the CF expander only).
The following have been corrected:
SC240 misdetection.
!
When the K toner cartridge is replaced, the
!
"previous PM counter" values for CMY are
all overwritten to the previous value for K
toner (SP7-906-23 to –25).
If machine enters Energy Saver 1 Mode
!
then cools down for more than 1 minute, it
will not display "Ready" after recovery
warm-up (only for G060-17 models).
When a B/W job is performed, the
!
coverage counters (SP7-833-1 to -4) for
CMY are not set to 0 as they should be, i.e.
the values from the previous job remain.
The following have been corrected:
Main scan magnification error
!
SC471 caused by stop timing error for
!
transfer belt contact motor.
SC545 in fusing phase control mode.
!
SC543
!
NOTE: This version has not been released
(see "side effect" in Version B1.18B).
SM
FIRMWARE
LEVEL
NUMBER
G0775623
(See Note 2)
G0775623 A
May 2002
14-3
FIRMWARE HISTORY
SERIAL
FIRMWARE
VERSION
March
B1.17C
2002
B1.18
G060