Firmware History for G060
DESCRIPTION OF MODIFICATION
Continued From Pervious Page
The New Coverage Counters will only
display the value of 999.99 and will not
function. The Coverage Counter
[7-833-05 to 08] provides image coverage
calculations for when Meter Charge Mode
(SP9-930 set to 0) is set to "OFF." Use the
Coverage Counter [SP7-833-05 to 08] if
Meter Charge Mode (SP9-930 set to 0) is
set to "OFF." Use the New Coverage
Counter [SP7-908-01 to 08] when Meter
Charge Mode (SP9-930 set to 1) is set to
"ON." SP7-908-5 to 8 displays the same
data as SP7-833-11 to -14.
The machine automatically detects
whether a 4kB or 8kB NVRAM is installed
on the BCU board.
A grid pattern has been added to SP mode
copy images. To activate this, it is
necessary to use system firmware ver1.07
or newer (for the CF expander only).
The following have been corrected:
SC240 misdetection.
When the K toner cartridge is replaced, the
"previous PM counter" values for CMY are
all overwritten to the previous value for K
toner (SP7-906-23 to –25).
If machine enters Energy Saver 1 Mode
then cools down for more than 1 minute, it
will not display "Ready" after recovery
warm-up (only for G060-17 models).
When a B/W job is performed, the
coverage counters (SP7-833-1 to -4) for
CMY are not set to 0 as they should be, i.e.
the values from the previous job remain.
The following have been corrected:
Main scan magnification error
SC471 caused by stop timing error for
transfer belt contact motor.
SC545 in fusing phase control mode.
SC543
NOTE: This version has not been released
(see "side effect" in Version B1.18B).
FIRMWARE
SERIAL
LEVEL
NUMBER
G0775623
March
2002
(See Note 2)
G0775623 A
May 2002
FIRMWARE
CHECK
VERSION
SUM
B1.17C
169B
B1.18
F284
Page 4 of 16