Gestetner G060 Service Manual page 211

Table of Contents

Advertisement

Rev. 03/2003
7
(Class 1, 2, and 3)
816
[Tray Clear] Paper Tray Counter Clear
1
Tray 1
2
Tray 2
3
Tray 3/LCT
4
Tray 4
6
Duplex
825
[Counter Reset]
1
Counter Reset
832
[Diag. Result] Diagnostic Result
1
Diag. Result
833
[Coverage] Pixel Coverage Ratio & No. of Toner Cartridges
1
Last [K]
2
Last [C]
3
Last [M]
4
Last [Y]
5
Average [K]
6
Average [C]
7
Average [M]
8
Average [Y]
11
Toner [K]
12
Toner [C]
13
Toner [M]
14
Toner [Y]
901
[Asset Info]
1
File Name
2
# of Lines
3
Location
905
[Alert Display]
7
Fusing: Alert
9
Oil: Alert
SM
Mode No.
*
P
P
*
P
*
P
*
*
PRINTER ENGINE SERVICE MODE
Function / [ Setting ]
Clears the counters (SP7-204) for the number of
sheets fed from the paper feed stations.
NOTE: The LCT is counted as the 3rd feed
station.
Rests the total counter values to "0".
NOTE: This SP mode can be done only once,
while the counter values are less than 0.
Displays the result of the diagnostics.
Displays the pixel coverage ratio for each color of
the last output.
[ 0 to 100.00 / - / 0.01 %/step ]
Displays accumulated average value of image
coverage ratio for each color.
[ 0 to 100.00 / - / 0.01 %/step ]
Displays the total number of toner cartridges
replaced.
[ 0 to 65535 / - / 1 cartridge/step ]
Records the location where a problem is detected
in the program. The data stored in this SP is used
for problem analysis. DFU
Specifies the timing for displaying the near-end
condition.
With the default setting, near-end is detected and
the alert lights on the panel 2.5K prints before
detecting the end condition. The unit life is 9303K
revolutions.
Increment: Delays the alert display timing.
Decrement: Hastens the alert display timing.
1.0K prints = approximately 93K revolutions
[ 0 to 20000 / 9070 / 1 K revolutions/step ]
Specifies the timing for displaying the near-end
condition.
With the default setting, near-end is detected and
the alert lights on the panel 2.5K prints before
detecting the end condition. The unit life is 1860
revolutions.
Increment: Delays the alert display timing.
Decrement: Hastens the alert display timing.
1.0K prints = 93
[ 0 to 10000 / 1628 / 1 K revolutions/step ]
5-43
G060

Advertisement

Table of Contents
loading

This manual is also suitable for:

G570G082