Rev. 09/2003
SC No.
Item
SC820
Self-diagnostics error: CPU
[0001]
CPU error
During the self-diagnostic, the
controller CPU detects an
to
error. There are 47 types of
[06FF]
error code (0001 to 4005)
depending on the cause of the
error. The CPU detects an
error and displays the specific
error code with the program
address where the error
occurs).
[0702]
CPU/Memory
Error
[0709]
[070A]
[0801]
CPU error
Same as [0001]
to
[4005]
SC 821
Self-diagnosis
The CPU checks if the ASIC
error: ASIC
timer works properly compared
[0D05]
with the CPU timer. If the ASIC
timer does not function in the
specified range, this SC code
is displayed.
SM
Definition
Possible Cause
[XXXX]: Detailed error code
• System firmware
problem
• Defective controller
• System firmware
problem
• Defective RAM-DIMM
• Defective controller
• System firmware
problem
• Defective RAM-DIMM
• Defective controller
4-29
Related
Troubleshooting Procedure
SCs
1. Turn the main switch off and on.
2. Reinstall the controller system
firmware.
3. Replace the controller.
When the problem cannot be fixed with
the above procedure, the following
information displayed on the screen
needs to be fed back to a technical
support center.
• SC code
• Detailed error code
• Program address
1. Turn the main switch off and on.
2. Reinstall the controller system
software.
3. Replace the RAM-DIMM.
4. Replace the controller.
1. Turn the main switch off and on.
2. Reinstall the controller system
firmware.
3. Replace the RAM-DIMM.
4. Replace the controller board.
SC TABLE
Type
CTL
CTL
CTL
CTL
G060