PRINTER ENGINE SERVICE MODE
3
(Class 1, 2, and 3)
906
[PC SelfChk] Process Control Self-checks
1
Job End
2
Interrupt
3
Non-use Time 1
4
Non-use Time 2
5
K Coefficient
G060
Mode No.
Function / [ Setting ]
*
Specifies the execution timing of the job end
process control self-check.
[ 0 to 999 / 200 / 1 print/step ]
The job end process control self-check is
automatically done after a job is completed when
200 prints have been made since the last self-
check.
The counter for the job end process control self-
check resets when one of the following process
control self-checks is done.
• Initial
• Interval: Interrupt
• Non-use Time
• During Toner End
When K prints are made, the number of prints is
calculated with the K coefficient in SP3-906-5.
*
Specifies the execution timing of the interrupt
process control self-check.
[ 0 to 999 / 0 / 1 print/step ]
The interrupt process control self-check is
automatically done if the number of prints in the
job exceeds the number set in this SP mode.
When the print job is completed, the counter is
reset, even if the interrupt self check did not occur.
When K prints are made, the number of prints is
calculated with the K coefficient in SP3-906-5.
*
Specifies the executing timing of the non-use time
process control self-check.
[ 0 to 999 / 0 / 1 print/step ]
0: Disable
The non-use time process control self-check is
automatically done after the number of prints set
with this SP mode have been made and no prints
have been made for the time set with SP mode 3-
906-4 since the last print job.
If the conditions are met, the self-check will be
done after the print job is completed.
The counter is reset when the initial process
control self-checks is done or when a print is
made.
*
Specifies the executing timing of the non-use time
process control self-check.
[ 0 to 2550 / 30 / 10 minutes/step ]
0: Disable
*
Sets the coefficient to calculate the counter value
for black-and-white prints.
[ 0 to 1.00 / 1.00 / 0.01/step ] DFU
With the default setting (100), counters used for
process control count up by 1 when 1 black-and-
white print has been made.
5-26