Gestetner G060 Service Manual page 209

Table of Contents

Advertisement

Mode No.
7
(Class 1, 2, and 3)
[Jam Paper Size]
506
4
A3
5
A4
13
B4
14
B5
32
11 x 17
36
8 1/2 x 14
38
8 1/2 x 11
44
5 1/2 x 8 1/2
128
Others
507
[Jam History]
1
Latest
2
Latest-1
3
Latest-2
4
Latest-3
5
Latest-4
6
Latest-5
7
Latest-6
8
Latest-7
9
Latest-8
10
Latest-9
[Firmware Ver.] Engine Firmware Version
801
1
Engine P/N
2
Duplex
3
Finisher
4
PSU/LCT
5
Mail Box
6
MUSIC P/N
11
MUSIC
12
Engine
803
[PM Counter]
(Sheets or Rotations, Unit, [Color])
Dev.: Development Unit, PF: Paper Feed Rollers, Oil Supply: Oil Supply Unit, Fusing:
Fusing Unit, Transfer: Transfer Unit
1
S:PCU [K]
2
S:PCU [Y]
3
S:PCU [M]
4
S:PCU [C]
5
S:Dev. [K]
6
S:Dev. [Y]
7
S:Dev. [M]
8
S:Dev. [C]
9
S:Oil Supply
10
PF By-pass
11
PF Tray 1
12
PF Tray 2
13
PF Tray 3/LCT
14
PF Tray 4
15
S:Fusing
16
S:Transfer
SM
PRINTER ENGINE SERVICE MODE
Function / [ Setting ]
*
Displays the number of jams according to the
P
paper size.
[ 0 to 9999 / 0 / 1 sheet/step ]
*
Displays the 10 most recently detected paper
P
jams.
*
Displays the part number of the firmware.
Displays the firmware version.
Displays the part number of the firmware.
Displays the firmware version.
*
Displays the number of sheets printed for each
current maintenance unit.
[ 0 to 9999999 / 0 / 1 sheet/step ]
PM counters click up based on the number of A4
(LT) LEF size sheets printed. Therefore, the A3
(DLT) Double Count is activated. The Double
Count cannot be deactivated.
When a unit is replaced, the machine
automatically detects that the new unit is installed.
Then, the current PM counter value is
automatically moved to the PM Counter - Previous
(SP7-906-1 to 9) and is reset to "0".
The total number of sheets printed with the last
unit replaced can be checked with SP7-906-1 to 9.
NOTE: The LCT is counted as the 3rd feed
station.
5-41
G060

Advertisement

Table of Contents
loading

This manual is also suitable for:

G570G082

Table of Contents