INSTALLATION REQUIREMENTS
1.1.3 MACHINE SPACE REQUIREMENT
Place the machine near the power source, providing clearance as shown.
575mm (23")
B
A
D
G082I801.WMF
A
G082I802.WMF
1.1.4 POWER REQUIREMENTS
!
CAUTION
1. Insert firmly the plug in the outlet.
2. Avoid using an outlet extension plug or cord.
3. Ground the machine.
1. Input voltage level: 120 V, 60 Hz: 11 A
2. Permissible voltage fluctuation: ±10 %
3. Do not put or place anything on the power cord.
G082
C
1450mm (57")
B
D
220 V ~ 240 V, 50 Hz/60 Hz: 6.6 A
1-2
A: Over 460 mm (18")
B: Over 100 mm (4")
C: Over 550 mm (22")
D: Over 700 mm (28")