Mmu Exceptions; Instruction Tlb Multiple Hit Exception - Hitachi SH7750 Hardware Manual

Sh7750 series superh risc engine
Hide thumbs Also See for SH7750:
Table of Contents

Advertisement

3.6

MMU Exceptions

There are seven MMU exceptions: the instruction TLB multiple hit exception, instruction TLB
miss exception, instruction TLB protection violation exception, data TLB multiple hit exception,
data TLB miss exception, data TLB protection violation exception, and initial page write
exception. Refer to figures 3.10 and 3.11 for the conditions under which each of these exceptions
occurs.
3.6.1

Instruction TLB Multiple Hit Exception

An instruction TLB multiple hit exception occurs when more than one ITLB entry matches the
virtual address to which an instruction access has been made. If multiple hits occur when the
UTLB is searched by hardware in hardware ITLB miss handling, a data TLB multiple hit
exception will result.
When an instruction TLB multiple hit exception occurs a reset is executed, and cache coherency is
not guaranteed.
Hardware Processing: In the event of an instruction TLB multiple hit exception, hardware
carries out the following processing:
1. Sets the virtual address at which the exception occurred in TEA.
2. Sets exception code H'140 in EXPEVT.
3. Branches to the reset handling routine (H'A000 0000).
Software Processing (Reset Routine): The ITLB entries which caused the multiple hit exception
are checked in the reset handling routine. This exception is intended for use in program
debugging, and should not normally be generated.
Rev. 6.0, 07/02, page 81 of 986