Bit 3—Framing Error (FER): Indicates whether or not a framing error has been found in the
data that is to be read next from SCFRDR2.
Bit 3: FER
0
1
Bit 2—Parity Error (PER): Indicates whether or not a parity error has been found in the data that
is to be read next from SCFRDR2.
Bit 2: PER
0
1
Rev. 6.0, 07/02, page 672 of 986
Description
There is no framing error that is to be read from SCFRDR2
[Clearing conditions]
Power-on reset or manual reset
When there is no framing error in the data that is to be read next from
SCFRDR2
There is a framing error that is to be read from SCFRDR2
[Setting condition]
When there is a framing error in the data that is to be read next from
SCFRDR2
Description
There is no parity error that is to be read from SCFRDR2
[Clearing conditions]
Power-on reset or manual reset
When there is no parity error in the data that is to be read next from
SCFRDR2
There is a parity error in the receive data that is to be read from SCFRDR2
[Setting condition]
When there is a parity error in the data that is to be read next from
SCFRDR2