sflow polling-interval (Interface)

Set the sFlow polling interval at an interface (overrides the global-level setting.)
Syntax
sflow polling-interval interval value
To return to the default, use the no sflow polling-interval interval command.
Parameters
interval value
Defaults
The same value as the current global default counter polling interval.
Command Modes
INTERFACE
Command
Version 8.3.16.1
History
Usage
This command sets the counter polling interval for an interface.
Information
Related
sflow polling-interval (Global)
Commands

sflow sample-rate (Global)

Change the global default sampling rate.
Syntax
sflow sample-rate value
To return to the default sampling rate, use the no sflow sample-rate command.
Parameters
value
Defaults
32768
Command Modes
CONFIGURATION
Command
Version 8.3.16.1
History
Usage
Sample-rate is the average number of packets skipped before the sample is taken. This command
Information
changes the global default sampling rate. You can configure an interface to use a different sampling
rate than the global sampling rate. If the value entered is not a correct power of 2, the command
generates an error message with the previous and next power of 2 value. Select one of these two packet
numbers and re-enter the command.
Enter the interval value in seconds.
Range: 15 to 86400 seconds
Default: The global counter polling interval
Introduced on MXL 10/40GbE Switch IO Module
Globally set the polling interval
Enter the sampling rate value.
Range: 256 to 8388608 packets
Enter values in powers of 2 only, for example 4096, 8192, 16384 etc.
Default: 32768 packets
Introduced on MXL 10/40GbE Switch IO Module