Dell Force10 MXL Blade Reference Manual page 686

Ftos command line reference guide for the mxl 10/40gbe switch io module
Hide thumbs Also See for Force10 MXL Blade:
Table of Contents

Advertisement

Example 2
Example 3
Example 4
686
|
Debugging and Diagnostics
In the above example, the "Status" field represents presence of OPTM ports, "Programmed version"
field represents loaded firmware version, and "SW version" represents SDK version.
Figure 39-4. show hardware stack-unit cpu data-plane statistics Command Example
.
FTOS#show hardware stack-unit 0 cpu data-plane statistics
bc pci driver statistics for device:
rxHandle
:0
noMhdr
:0
noMbuf
:0
noClus
:0
recvd
:0
dropped
:0
recvToNet
:0
rxError
:0
rxDatapathErr
:0
rxPkt(COS0)
:0
rxPkt(COS1)
:0
rxPkt(COS2)
:0
rxPkt(COS3)
:0
rxPkt(COS4)
:0
rxPkt(COS5)
:0
rxPkt(COS6)
:0
rxPkt(COS7)
:0
rxPkt(UNIT0)
:0
transmitted
:1696
txRequested
:1696
noTxDesc
:0
txError
:0
txReqTooLarge
:0
txInternalError :0
txDatapathErr
:0
txPkt(COS0)
:0
txPkt(COS1)
:0
txPkt(COS2)
:0
txPkt(COS3)
:0
txPkt(COS4)
:0
txPkt(COS5)
:0
txPkt(COS6)
:0
txPkt(COS7)
:0
txPkt(UNIT0)
:0
FTOS#
Figure 39-5. show hardware stack-unit cpu party-bus statistics Command Example
FTOS#show hardware stack-unit 0 cpu party-bus statistics
Input Statistics:
8189 packets, 8076608 bytes
0 dropped, 0 errors
Output Statistics:
366 packets, 133100 bytes
0 errors
FTOS#
Figure 39-6. show hardware stack-unit drops (drop summary for entire switch)
Command Example
FTOS#show hard stack-unit 0 drops
UNIT No: 0
Total Ingress Drops
Total IngMac Drops
Total Mmu Drops
Total EgMac Drops
Total Egress Drops
FTOS#
: 7841475
: 0
: 0
: 0
: 43321

Advertisement

Table of Contents
loading

Table of Contents