Dell Force10 MXL Blade Reference Manual page 74

Ftos command line reference guide for the mxl 10/40gbe switch io module
Hide thumbs Also See for Force10 MXL Blade:
Table of Contents

Advertisement

Usage
Information
74
|
Control and Monitoring
Figure 4-31. show tech-support Command Example (Partial)
FTOS#show tech-support stack-unit 0
Required Type
:
--
Unit 5 --
Unit Type
: Member Unit
Status
: not present
Required Type
:
----------------------------------- show environment -------------------
-- Unit Environment Status
Unit
Status
Temp
---------------------------------------------------------------------------
* 1
online
41C
* Management Unit
--
Thermal Sensor Readings (deg C)
Unit
Sensor0
Sensor1
---------------------------
1
39
41
----------------------------------- show ip traffic -------------------
IP statistics:
Rcvd: 894390 total, 415557 local destination
0 format errors, 0 checksum errors, 0 bad hop count
0 unknown protocol, 0 not a gateway
15 security failures, 0 bad options
Frags: 0 reassembled, 0 timeouts, 0 too big
0 fragmented, 0 couldn't fragment
Bcast: 402 received, 0 sent; Mcast: 37 received, 0 sent
Sent: 468133 generated, 0 forwarded
42 encapsulation failed, 0 no route
ICMP statistics:
Rcvd: 0 format errors, 0 checksum errors, 0 redirects, 2 unreachable
0 echo, 0 echo reply, 0 mask requests, 0 mask replies, 0 quench
0 parameter, 0 timestamp, 0 info request, 0 other
Sent: 0 redirects, 0 unreachable, 0 echo, 0 echo reply
0 mask requests, 0 mask replies, 0 quench, 0 timestamp
0 info reply, 0 time exceeded, 0 parameter problem
UDP statistics:
Rcvd: 396516 total, 0 checksum errors, 0 no port
0 short packets, 0 bad length, 28746 no port broadcasts, 0 socket full
Sent: 16460 total, 28746 forwarded broadcasts
TCP statistics:
Rcvd: 4618 total, 0 checksum errors, 0 no port
Sent: 5023 total
ARP statistics:
Rcvd: 43988 requests, 24518 replies, 10 wrong interface
Sent: 42 requests, 6 replies (0 proxy)
Without the page or stack-unit option, the command output is continuous, use Ctrl-z to interrupt the
command output.
The save option works with other filtering commands. This allows you to save specific information of
a show command. The save entry must always be the last option.
For example:
FTOS#show tech-support |grep regular-expression |
regular-expression | save flash://result
-
-
--
Voltage
ok
--
except
find
regular-expression |

Advertisement

Table of Contents
loading