Defaults
Command Modes
Command
History

offline stack-unit

Syntax
Parameters
Defaults
Command Mode
Command
History
Usage
Information
676
|
Debugging and Diagnostics
level0
Enter the keyword
presence of various components and perform essential path verifications. In addition, they
verify the identification registers of the components on the board.
level1
Enter the keyword
diagnostic tests with support for automatic partitioning. They perform status/self test for all
the components on the board and test their registers for appropriate values. In addition, they
perform extensive tests on memory devices (e.g., SDRAM, flash, NVRAM, EEPROM, and
CPLD) wherever possible. There are no tests on 10G links. At this level, stack ports are shut
down automatically.
level2
Enter the keyword
diagnostic tests with no support for automatic partitioning. Level 2 diagnostics are used
primarily for on-board loopback tests and more extensive component diagnostics. Various
components on the board are put into loop back mode, and test packets are transmitted
through those components. These diagnostics also perform snake tests using VLAN
configurations. You must physically remove the unit from the stack to test 10G links.
verbose
Enter the keyword
information in the output than standard mode.
no-reboot
Enter the keyword
diagnostic execution. Generally, this option is never used because if you run the diagnostic
once again without rebooting the chassis, it may cause an issue with the diagnostic results.
none
EXEC Privilege
Version 8.3.16.1
Introduced on MXL 10/40GbE Switch IO Module
Place a stack unit in the offline state.
offline stack-unit number
number
none
EXEC Privilege
H
Version 8.3.16.1
Introduced on MXL 10/40GbE Switch IO Module
The system reboots when the off-line diagnostics complete. This is an automatic process. A warning
message appears when the
offline stack-unit
Warning - Diagnostic execution will cause stack-unit to reboot after
completion of diags.
Proceed with Offline-Diags [confirm yes/no]:y
level0
to run Level 0 diagnostics. Level 0 diagnostics check for the
Level1
to run Level 1 diagnostics. Level 1 diagnostics is a smaller set of
level2
to run Level 2 diagnostics. Level 2 diagnostics is a full set of
verbose
to run the diagnostic in verbose mode. Verbose mode gives more
no-reboot
to avoid automatic rebooting of the chassis after completion of
Enter the stack unit number.
Range: 0 to 5
command is implemented.