Siemens SINUMERIK 840D Diagnostics Manual page 95

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
10256
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10257
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10258
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10259
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
[up to SW 3.x only] Channel %1 reorg sequence canceled
%1 = Channel number
Internal sequence error. REORG is not possible at present - program abort.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Press RESET.
Clear alarm with the RESET key. Restart part program.
[up to SW 3.x only] Channel %1 reorg sequence canceled
%1 = Channel number
Internal sequence error. REORG is not possible at present - program abort.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Press RESET.
Clear alarm with the RESET key. Restart part program.
[up to SW 3.x only] Mode group %2 channel %1: ID invalid or duplicated
%1 = Channel number
%2 = Mode group number
An invalid channel/mode group assignment was detected on power-up.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Check machine data ASSIGN_CHAN_TO_MODE_GROUP.
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
[up to SW 3.x only] Channel %1
%1 = Channel number
REORG is not possible at present.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
--
Switch control OFF - ON.
1 Alarms
1-95

Advertisement

Table of Contents
loading