• Impossible due to embargo regulations:
• 1. Synchronous actions: Writing of feed, override and axial offsets ($AA_VC, $AC_VC,
$AA_OVR, $AA_VC and $AA_OFF) from synchronous actions as well as Continuous
Dressing can be programmed only once in a block.
• 2. Extended measurement: 'Cyclic measurement' (MEAC) and 'Measurement from syn-
chronous action' is not possible.
• 3. Axis interpolation: The number of axes interpolating with one another must not exceed
4 (this also includes synchronous coupling of axes via synchronous actions "DO
POS[X]=$A..." "DO FA[X]=$A...").
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Modify part program.
Clear alarm with the RESET key. Restart part program.
[up to SW 3.x] Channel %1 NC start with active alarm not allowed
%1 = Channel number
An alarm is currently active, the internal reaction to which is to inhibit an NC start.
- Alarm display.
Find and eliminate the cause of the alarm.
Clear alarm with NC START or RESET key and continue the program.
[up to SW 3.x] Channel %1 NC start not possible
%1 = Channel number
NC start is not accepted because, e.g.
• REORG is still active
• Delete distance-to-go is still active
• The system is waiting for another channel.
- Alarm display.
Press NC Start again.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 NC start without reference point (action=%2<ALNX>)
%1 = Channel number
%2 = Action number/action name
NC start has been activated in the MDA or AUTOMATIC mode and at least one axis that
needs to be referenced has not reached its reference point.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Via the channel-specific MD
20700: REFP_NC_START_LOCK (NC Start without reference point) you can decide
whether the axis must be referenced before NC Start or not. The start of referencing can
be enabled channel-specific or axis-specific.