10.04
Reactions:
Remedy:
Program Continuation:
300747
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300748
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300749
Parameters:
Definitions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Enable the function SBH/SG
via MD 1301: $MD_SAFE_FUNCTION_ENABLE (safe functions enable).
Switch control OFF - ON.
Axis %1 drive %2 monitoring cycle time MD 1300 invalid
%1 = NC axis number
%2 = Drive number
Check and, if necessary, correct MD 1300: $MD_SAFETY_CYCLE_TIME (monitoring
cycle) has not been set as a multiple of the NC position control cycle.
Request: During boot-up of the control.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Set the monitoring cycle via
MD 1300 to n * NC position control cycle, n must be >= 1.
Switch control OFF - ON.
Axis %1 drive %2 monitoring cycle times of both axes differ
%1 = NC axis number
%2 = Drive number
The monitoring cycles set in MD 1300: $MD_SAFETY_CYCLE_TIME (monitoring cycle)
for the two axes of a 2-axis module are not identical.
Request: During boot-up of the control.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Check and, if necessary, cor-
rect MD 1300: $MD_SAFETY_CYCLE_TIME (monitoring cycle) on all drives of the mod-
ule.
Switch control OFF - ON.
Axis %1 drive %2 conversion factor between motor and load too large
%1 = NC axis number
%2 = Drive number
The conversion factor from the motor system [increments] to the load system [µm/mdeg]
is larger than 1 or the factor which converts the load system to the motor system is larger
than 65535.