Siemens SINUMERIK 840D Diagnostics Manual page 90

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
Definitions:
Reactions:
Remedy:
Program Continuation:
10209
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10220
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10221
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10222
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-90
After block search with calculation, the control is in the desired state. The program can
now be started with NC Start or the state can be changed for the time being with over-
store/jog.
- Interpreter stop
- Alarm display.
- NC Stop on alarm.
Press NC Start.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 internal NC stop after block search
%1 = Channel number
Internal alarm which initiates an NC Stop. The alarm is output if
$MN_SEARCH_RUN_MODE ==1 and the last action block is activated after block search
in the main run. Alarm 10208 is activated depending on the VDI signal PLC -> NCK chan-
nel DBB1.6.
- Interpreter stop
- NC Stop on alarm.
NC-Start
Clear alarm with NC START or RESET key and continue the program.
[up to SW 3.x only] Channel %1 active
%1 = Channel number
The internal command "delete NC blocks prepared by preprocessor and reorganize
(REORG)" has been requested for this channel. It is initiated, e.g. as a result of an over-
store, but cannot be executed in a running channel.
- Alarm display.
Stop the channel (NC Stop) and repeat the action.
Clear alarm with the Delete key or NC START.
[up to SW 3.x only] Channel %1 not stopped at end of block
%1 = Channel number
The reorganization of NC blocks starting at the current block (REORG) is only possible at
the end of the block.
- Alarm display.
Stop the channel (NC Stop) and repeat the action.
Clear alarm with the Delete key or NC START.
Channel %1 inter-channel communication not possible
%1 = Channel number
This channel has received a negative acknowledgment from the inter-channel communi-
cation because the destination channel number is not known, e.g.: START(x) or
WAITE(x) but channel x has not been initialized
- Alarm display.
This is an indication of possible discrepancies. The program continues if no acknowledg-
ment is called for.
Clear alarm with the Delete key or NC START.
 Siemens AG, 2004. All rights reserved