Siemens SINUMERIK 840D Diagnostics Manual page 33

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
4020
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4021
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4022
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Identifier %1 used several times in machine data %2
%1 = String: Name of identifier
%2 = String: MD identifier
When determining a name in the NCK tables (arrays) for: machine axes, Euler angles,
direction vectors, interpolation parameters and intermediate point coordinates, an identi-
fier has been used that is already in the control.
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Select for the identifier to be
entered a character string that is not yet used in the system (max. 32 characters).
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Channel %1 identifier %2 used several times in machine data %3
%1 = Channel number
%2 = String: Name of identifier
%3 = String: MD identifier
To determine the name in the channel-specific tables for geometry axes and channel
axes an identifier already existing in the control has been used.
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Select for the identifier to be
entered a character string that is not yet used in the system (max. 32 characters).
Switch control OFF - ON.
Axis container %3 switch not allowed: ext. zero offset active channel %1 axis %2
%1 = Channel
%2 = Axis/spindle
%3 = Axis container number
The axis container switch enable cannot be given because an external zero offset is
active.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
The program must be aborted with the RESET key and the external zero point offset
deselected before the container is advanced.
Clear alarm with the RESET key. Restart part program.
1 Alarms