10.04
70010
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
70011
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
70012
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
70013
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Channel %1 block %2 unreachable point on selection
%1 = Channel number
%2 = Block number
On transformation selection, the machine axes are positioned with the joint rod not reach-
ing the platform.
This cannot happen with a machine that has been started up properly.
If the joints have not yet been connected with the platform on start-up, this alarm will show
an impermissible position of the machine axes.
- Interpreter stop
- Alarm display.
Modify machine data or approach other selection position
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 unreachable point
%1 = Channel number
%2 = Block number
The selected block includes a position outside the possible working range of the machine
tool.
- Local alarm reaction.
- Alarm display.
Modify parts program
Clear alarm with the RESET key. Restart part program
Channel %1 unreachable point
%1 = Channel number
Failure in the cyclic backward transformation in the interpolator or in the forward transfor-
mation, e.g. after RESET.
Extreme distortions of the mechanical system in the current point may be the reason.
- NC Start disable in this channel.
- Alarm display.
- NC Stop on alarm.
Deselect transformation and relieve mechanism
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 axis %3 reaches angle %4 on platform
%1 = Channel number
%2 = Block number
%3 = Channel axis
%4 = Limit angle "+" or "-"
The indicated block includes a position on which the limit angles on the platform are
exceeded, see MD 62126 und 62127.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
Modify parts program block
Clear alarm with the RESET key. Restart part program