1 Alarms
Reactions:
Remedy:
Program Continuation:
20056
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20057
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20058
Parameters:
Definitions:
1-316
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. If the revolutional feed is also
to be active in JOG mode, then a master spindle must be declared via the channel-spe-
cific machine data 20090 SPIND_DEF_MASTER_SPIND. In this case you have to open a
screen in the PARAMETER operating area with the softkeys "SETTINGDATA" and "JOG
DATA" and preselect the G function G95 there. The JOG feedrate can then be entered in
[mm/rev]. (If 0 mm/rev is set as JOG feed, the control takes the value assigned in the axis-
specific MD 32050 JOG_REV_VELO or in the case of rapid traverse overlay 32040
JOG_REV_VELO_RAPID).
The revolutional feed in JOG mode is deactivated by changing the G function from G95 to
G94.
Clear alarm with the Delete key or NC START.
Channel %1 axis %2 no revolutional feedrate possible. Axis/spindle %3 stationary
%1 = Channel number
%2 = Axis name, spindle number
%3 = Axis name, spindle number
An axis is to travel in JOG with revolutional feed, but the spindle/axis the feed is to be
derived from is 0.
- Alarm display.
Traverse the spindle/axis from which the feed is to be derived.
Alarm display showing cause of alarm disappears. No further operator action necessary.
Channel %1 block %2 revolutional feedrate for axis/spindle %3 is <= zero
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Revolutional feed has been programmed for an axis/spindle, but the velocity was not pro-
grammed or the programmed value is smaller than or equal to zero.
- Correction block is reorganized.
- Local alarm reaction.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department.
• Correct the part program or
• Specify the correct feed for PLC axes at the VDI interface,
• Specify feed for oscillating axes in the setting data $SA_OSCILL_VELO.
Clear alarm with the RESET key. Restart part program
Channel %1 axis %2 revolutional feedrate: illegal feed source
%1 = Channel number
%2 = Axis name, spindle number
An axis/spindle is to be traversed at revolutional feedrate. The reference axis/spindle
defined in SD 43300 ASSIGN_FEED_PER_REV_SOURCE refers to itself. The coupling
caused cannot be executed.
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition