1 Alarms
10230
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10231
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10232
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10240
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10241
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-92
[up to SW 3.x only] Mode group %2 channel %1 program interruption does not per-
mit mode change
%1 = Channel number
%2 = Mode group number
While in the "program interrupted" status (interface signal DB 21 - 28, DBX 35.3) - trig-
gered by an NC Stop followed by a mode change to JOG - it is only possible to change
back to the previous mode (AUTOMATIC or MDA).
- Alarm display.
You can change the mode via the "program aborted" status (interface signal DB 21 - 28,
DBX 35.4) - triggered by a "reset".
Clear alarm with the Delete key or NC START.
[up to SW 3.x only] Mode group %2 channel %1 program stop does not permit
mode change
%1 = Channel number
%2 = Mode group number
While in the "program stopped" status (interface signal DB 21 - 28, DBX 35.2, triggered by
an NC Stop), it is only possible to change back to continuous program operation (by
means of an NC Start).
- Alarm display.
You can change the mode via the "program aborted" status (interface signal DB 21 - 28,
DBX 35.4) - triggered by a "reset".
Clear alarm with the Delete key or NC START.
[up to SW 3.x only] Mode group %2 channel %1 does not permit mode change
%1 = Channel number
%2 = Mode group number
The change to the desired mode is not permitted. You can only perform the mode change
in the "reset" state.
- Alarm display.
You can change the mode by pressing the Reset key and repeating the mode change.
Clear alarm with the Delete key or NC START.
[up to SW 3.x only] Mode group %2 channel %1 mode change not possible
%1 = Channel number
%2 = Mode group number
The mode change would cause the "reorganization" of the preprocessor buffer. This is not
possible at present, because a complex geometry section is being processed.
- Alarm display.
You can change the mode by pressing the Reset key and repeating the mode change.
Clear alarm with the Delete key or NC START.
[up to SW 3.x only] Mode group %2 mode change in active channel %1 not possible
%1 = Channel number
%2 = Mode group number
The channel is not in the stopped state. Reorganization is therefore impossible.
- Alarm display.
Press NC Stop and perform the action again.
Clear alarm with the Delete key or NC START.