1 Alarms
10701
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10702
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10703
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10704
Parameters:
Definitions:
Reactions:
1-104
Channel %1 block %2 channel-specific protection zone %3 violated during auto-
matic or MDA mode
%1 = Channel number
%2 = Block number
%3 = Protection zone number
The workpiece-related channel-specific protection zone has been violated. Note that
another tool-related protection zone is still active. The workpiece-related protected area
can be traversed after a new NC Start.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Protection zone can be traversed after a new NC Start.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 NCK protection zone %2 violated during manual mode
%1 = Channel number
%2 = Protection zone number
The workpiece-related NCK protection zone has been violated. Note that another tool-
related protection zone is still active. The workpiece-related protected area can be tra-
versed after a new NC Start.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
Protection zone can be traversed after a new NC Start.
Alarm display showing cause of alarm disappears. No further operator action necessary.
Channel %1 channel-specific protection zone %2 violated during manual mode
%1 = Channel number
%2 = Protection zone number
The workpiece-related channel-specific protection zone has been violated. Note that
another tool-related protection zone is still active. The workpiece-related protected area
can be traversed after a new NC Start.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
Protection zone can be traversed after a new NC Start.
Alarm display showing cause of alarm disappears. No further operator action necessary.
Channel %1 block %2 protection zone monitoring is not guaranteed
%1 = Channel number
%2 = Block number, label
New movements of a geometry axis which have been added could not be allowed for at
the time of block preparation. It is therefore not certain that the protection zones will not
be violated. This is just a warning message without further reactions.
- Interface signals are set.
- Alarm display.