Siemens SINUMERIK 840D Diagnostics Manual page 102

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
10652
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10653
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10654
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10655
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-102
Channel %1 axis %2 gantry warning threshold exceeded
%1 = Channel number
%2 = Axis
The gantry following axis has exceeded the warning limit specified in MD 37110
GANTRY_POS_TOL_WARNING.
- Alarm display.
Please inform the authorized personnel/service department.
1. Check axis (uneven mechanical movement?)
2. MD not set correctly (MD 37110 GANTRY_POS_TOL_WARNING). Changes to this
MD take effect after a RESET.
Alarm display showing cause of alarm disappears. No further operator action necessary.
Channel %1 axis %2 gantry error threshold exceeded
%1 = Channel number
%2 = Axis
The gantry following axis has exceeded the error limit (actual value tolerance) specified in
MD 37120 GANTRY_POS_TOL_ERROR.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department.
1. Check axis (uneven mechanical movement?)
2. MD not set correctly (MD 37120 GANTRY_POS_TOL_ERROR). A POWER ON is nec-
essary after modifying the MD.
If the axes are not yet referenced, MD GANTRY_POS_TOL_REF is the trigger condition
for the error message.
Clear alarm with the RESET key. Restart part program.
Channel %1 waiting for synchronization start of gantry group %2
%1 = Channel number
%2 = Gantry unit
Alarm message appears when the axes are ready for synchronization. The gantry unit
can now be synchronized. The actual value difference between master and slave axis is
greater than the gantry warning threshold MD 37110 GANTRY_POS_TOL_WARNING.
The synchronization must be started again explicitly with the start gantry synchronization
interface signal (DB31-48, DBX 29.4).
- Alarm display.
Please inform the authorized personnel/service department. See Description of Functions
(Special Functions), G1 Gantry Axis
Alarm display showing cause of alarm disappears. No further operator action necessary.
Channel %1 synchronization of gantry group %2 in progress
%1 = Channel number
%2 = Gantry unit
No further explanation.
- Alarm display.
--
Alarm display showing cause of alarm disappears. No further operator action necessary.
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition