10.04
Reactions:
Remedy:
Program Continuation:
27241
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
27242
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
• Increase MD $MN_PLC_RUNNINGUP_TIMEOUT
• Check the PLC operating status.
• Check the PLC operating system software version.
• Delete the F parameterization in the NCK MD.
Switch control OFF - ON.
PROFIsafe: DP M version different, NCK: %1, PLC: %2
%1 = DP interface version of the NCK
%2 = DP interface version of the PLC
The NCK and PLC components have different implementations of the DP interface. The F
communication cannot be initialized.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
• Check the PLC operating system and NCK software versions.
• Upgrade the PLC operating system.
• Delete the NCK F parameterization.
Switch control OFF - ON.
PROFIsafe: F module %1, %2 faulty
%1 = PROFIsafe address
%2 = Incorrect F parameter
An error was detected during the evaluation of the F parameters.
%2 = CRC1: CRC specified by F parameters faulty.
%2 = F_WD_Timeout: The monitoring time parameterized in Step 7 is too small for the
PROFIsafe cycle time defined by the MD $MN_PROFISAFE_IPO_TIME_RATIO.
%2 = CRC2_Len: CRC message length faulty.
%2 = F_Data_Len: the telegram length defined for the specified module is incorrect.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
%2 = CRC1: PLC overall reset, reload the S7 F configuration.
%2 = F_WD_Timeout: reparameterize the PROFIsafe cycle time or F monitoring time.
%2 = CRC2_Len: PLC overall reset, reload the S7 F configuration.
%2 = F_Data_Len: PLC overall reset, reload the S7 F configuration.
Switch control OFF - ON.