Siemens SINUMERIK 840D Diagnostics Manual page 32

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
Reactions:
Remedy:
Program Continuation:
4018
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4019
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-32
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Correct and complete the container location assignments. Check the machine data for the
logical axis assignment table (MN_AXCONF_LOGIC_MACHAX_TAB)
Switch control OFF - ON.
Axis container %1, location %2 not used by any channel
%1 = Axis container number
%2 = Axis container location
The container location is not referenced by any channel.
- NC not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Correct and complete the container location assignments. Check machine data
MC_AXCONF_MACHAX_USED and MN_AXCONF_LOGIC_MACHAX_TAB.
Switch control OFF - ON.
Axis container %1 advance not allowed with current status of NCU %2
%1 = NCU number
%2 = Axis container number
This error only occurs with direct advancing of the container. With direct container
advancing, only one channel is allowed to activate the NC language command for
advancing the container. In order to ensure this, the other channels must have the reset
status and the axes must be stationary.
With NCU link, the above condition applies to all channels of the NCU group.
Error parameters:
• 1 : NC Ready missing
• 16: At least one other channel is active
• 35: AXCT axis is active following axis/spindle
• 36: AXCT axis is active leading axis
• 39: Axis/spindle disable active
• 40: Overlaid motion active for AXCT axis
• 41: Axis replacement active for AXCT axis
• 42: Interpolator active for one axis container axis
• 46: Rotating spindle with different Ipo cycle of NCUs
• 47: New-Config active
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
The program must be canceled with Reset and the zero offset deselected before activat-
ing the axis container switch.
Clear alarm with the RESET key. Restart part program.
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents