Siemens SINUMERIK 840D Diagnostics Manual page 151

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Reactions:
Remedy:
Program Continuation:
12340
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12350
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- Correction block
- Interface signals are set.
- Alarm display.
Press the NC Stop key and select the function "Correction block" with the softkey PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block. Check transfer
parameters of the subroutine call and define the application accordingly as call-by-value
or call-by-reference parameter.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 number of parameters too high %3
%1 = Channel number
%2 = Block number, label
%3 = Source string
When calling a function or a procedure (predefined or user-defined) more parameters
were transferred than defined.
Predefined functions and procedures: The number of parameters has been set perma-
nently in the NCK.
User-defined functions and procedures: The number of parameters is established by type
and name in the definition.
- Correction block
- Interface signals are set.
- Alarm display.
Press the NC Stop key and select the function "Correction block" with the softkey PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block. Check whether
the correct procedure/function has been called. Program the number of parameters in
accordance with the procedure/function.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 parameter %3 no longer possible
%1 = Channel number
%2 = Block number, label
%3 = Source string
An attempt has been made to transfer actual parameters although axis parameters
located before them have not been assigned. For procedure or function calls, assignment
of parameters that are no longer required can be omitted, if subsequently no further
parameters are to be transferred. Example: N10 FGROUP(X, Y, Z, A, B) ; max. 8 axes
possible The following call-by-value parameters would then be initialized with zero
because the space-dependent assignment has been lost on account of the omitted axis
parameters.
Axes that can be omitted and following parameters do not occur in the predefined proce-
dures and functions.
- Correction block
- Interface signals are set.
- Alarm display.
Press the NC Stop key and select the function "Correction block" with the softkey PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block. In predefined
procedures and functions either remove the following parameters or transfer any preced-
ing axis parameters. In user-defined procedures and functions, parameter transfer must
be programmed in accordance with the instructions given in the machine manufacturer's
programming guide.
Clear alarm with NC START or RESET key and continue the program.
1 Alarms
1-151

Hide quick links:

Advertisement

Table of Contents
loading