10.04
Reactions:
Remedy:
Program Continuation:
4010
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4011
Parameters:
Definitions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Correct $MA_AXCONF_ASSIGN_MASTER_NCU and/or
$MN_AXCONF_LOGIC_MACHAX_TAB.
Switch control OFF - ON.
Invalid identifier used in machine data %1[%2]
%1 = String: MD identifier
%2 = Index: MD array
When determining a name in the NCK tables (arrays) for: machine axes, Euler angles,
direction vectors, interpolation parameters and intermediate point coordinates, one of the
following syntax rules for the identifier to be entered has been violated:
• The identifier must be an NC address letter (A, B, C, I, J, K, U, V, W, X, Y, Z), possibly
with a numerical extension (840D: 1-99, FM-NC: 1-9)
• The identifier must begin with 2 arbitrary capital letters but not with $ (reserved for sys-
tem variable).
• The identifier must not be a keyword of the NC language (e.g. POSA).
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Enter the identifier for user-
defined names with correct syntax in the displayed MD.
• Machine axes: AXCONF_MACHAX_NAME_TAB
• Euler angles: EULER_ANGLE_NAME_TAB
• Normal vectors: NORMAL_VECTOR_NAME_TAB
• Direction vectors: 10640 DIR_VECTOR_NAME_TAB
• Interpolation parameters: 10650 IPO_PARAM_NAME_TAB
• Intermediate point coordinates: 10660 INTERMEDIATE_POINT_NAME_TAB
Switch control OFF - ON.
Channel %1 invalid identifier used in machine data %2[%3]
%1 = Channel number
%2 = String: MD identifier
%3 = Index: MD array
When defining names in the channel-specific tables for geometry axes and channel axes,
one of the following syntax rules for the identifier to be entered has been violated:
• The identifier must be an NC address letter (A, B, C, I, J, K, U, V, W, X, Y, Z), possibly
with a numerical extension (840D: 1-99, FM-NC: 1-9).
• The identifier must begin with 2 arbitrary capital letters but not with $ (reserved for sys-
tem variable).
• The identifier must not be a keyword of the NC language (e.g. POSA).