Siemens SINUMERIK 840D Diagnostics Manual page 620

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
Reactions:
Remedy:
Program Continuation:
301713
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
301714
Parameters:
Definitions:
Reactions:
Remedy:
1-620
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Set MD_1021 $MD_ENC_ABS_TURNS_MOTOR (resolution number revolution) to 0.
Switch control OFF - ON.
Axis %1 drive %2 resolution SSI direct measuring system invalid
%1 = NC axis number
%2 = Drive number
Configuration of the direct measuring system is faulty for SSI encoder: MD_1032
$MD_ENC_ABS_RESOL_DIRECT must not be 0.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
• Set MD_1032 $MD_ENC_ABS_RESOL_DIRECT to the correct value:
• Rotary encoder: Singleturn resolution (increments per revolution).
• Linear encoder: Resolution of an increment (in nanometers).
Switch control OFF - ON.
Axis %1 drive %2 transmission length SSI direct measuring system invalid
%1 = NC axis number
%2 = Drive number
Configuration of the direct measuring system is faulty for SSI encoder: MD_1041
$MD_NO_TRANSMISSION_BITS_DM (SSI transmission length) is smaller than the num-
ber of all parameterized bits in MD_1031 $MD_ENC_ABS_TURNS_DIRECT (multiturn),
MD_1032 $MD_ENC_ABS_RESOL_DIRECT (singleturn) and MD_1037
$MD_ENC_CONFIG_DIRECT Bit 14 (alarm bit) and MD_1037
$MD_ENC_CONFIG_DIRECT Bit 12 (parity bit).
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
• Set parameters correctly for all associated machine data:
• MD_1041 $MD_NO_TRANSMISSION_BITS_DM (SSI transmission length): number of
bits in an SSI protocol, including all bits such as alarm bit and parity bit.
• MD_1031 $MD_ENC_ABS_TURNS_DIRECT (multiturn): number of resolvable revolu-
tions
• MD_1032 $MD_ENC_ABS_RESOL_DIRECT (singleturn): number of increments per
revolution
• MD_1037.Bit 12 $MD_ENC_CONFIG_DIRECT.Bit 12: parity bit
• MD_1037.Bit 14 $MD_ENC_CONFIG_DIRECT.Bit 14: alarm bit
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04