6030
Definitions:
Reactions:
Remedy:
Program Continuation:
6035
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
6100
Parameters:
Definitions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Limit of user memory has been adapted
Data management checks during power-up the actually available physical user memory
(DRAM, DPRAM and SRAM) with the values in the system-specific machine data 18210
MM_USER_MEM_DYNAMIC, MD 18220 MM_USER_MEM_DPR und MD 18230 MM_-
USERMEM_BUFFERED.
- Alarm display.
No remedial measures are required. The new maximum permissible value can be read
from the reduced machine data.
Clear alarm with the RESET key. Restart part program.
Instead of %1 KB the system has only %2 KB of free user memory of type '%3'
%1 = Free memory capacity in KB defined for the control model
%2 = Actual maximum capacity of free memory in KB
%3 = Type of memory, "D"=non-battery-backed, "S"=battery-backed
The alarm can only occur after a 'cold start' (=NCK start-up with standard machine data).
The alarm is only a notice. There is no interference with any NCK functions. It shows that
the NCK has less free user memory available than specified by Siemens for this control
variant. The value of the actually available free user memory can also be taken from the
machine data $MN_INFO_FREE_MEM_DYNAMIC, $MN_INFO_FREE_MEM_STATIC.
Siemens supplies NCK with default settings that, depending on the model, have certain
(free) memory space available for the specific settings of the actual applications. The orig-
inal factory setting of NCK systems is thus that the alarm does not occur with a cold start.
- Alarm display.
Reasons for the message:
• The NCK contains compile cycle software, that uses so much memory space that the
hardware cannot provide the required memory.
• The NCK runs on hardware that is not intended for this NCK release (i.e. that has not
enough memory capacity).
• If the application runs properly with the remaining free user memory (i.e. can be started
up without any errors), the message can simply be ignored.
• If the actual application cannot be configured because there is not enough memory
capacity available, either the existing compile cycle must be reduced or, if possible, the
system must be upgraded with additional memory space.
Clear alarm with the RESET key. Restart part program.
Error while creating %1, error number %2 %3
%1 = Symbolname
%2 = Error code
%3 = If required, internal error identifier
An error was detected while creating a compile cycle machine data. The error number
specifies the type of error.
• Error number 1: Insufficient memory available
• Error number 2: Symbol in the NCK already exists
• Error number 3: Maximum possible number of symbols exceeded
• Error number 4: Invalid name prefix
• Error number 5: Illegal array size
Note: Other errors of this type could have occurred, but have not been displayed.