1 Alarms
Definitions:
Reactions:
Remedy:
Program Continuation:
15000
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15010
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15020
Parameters:
Definitions:
1-234
When programming a circle by means of an intermediate point (CIP) all 3 points (initial,
end and intermediate points) are on a straight line and the intermediate point (pro-
grammed by means of interpolation parameters I, J, K) is not located between the initial
and end points.
If the circle is the component of a helix, the specified number of turns (keyword TURN=...)
determines further block processing:
• TURN>0: alarm display because the circle radius is infinitely great.
• TURN=0 and CIP specified between initial and end points. A straight line is generated
between the initial and end points (without alarm message).
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Locate the position of the intermediate point with the parameters I, J and K in such a way
that it actually is located between the initial and end points of the circle or do not make
use of this type of circle programming and instead program the circle with radius or open-
ing angle or center point parameters.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 channel-sync instruction using illegal mark
%1 = Channel number
%2 = Block number, label
A WAITM/WAITMC/SETM/CLEARM instruction was programmed with a marker number
that was less than 1 or greater (MAXNUM_MARKER * MAXNUM_CHANNELS).
Exception: CLEARM(0) is allowed and clears all markers in channel!
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Correct the instruction accordingly.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 program coordination instruction with invalid channel num-
ber
%1 = Channel number
%2 = Block number, label
A WAITM, WAITMC,INIT or START instruction was programmed with an invalid channel
number.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Correct the instruction accordingly.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 CHANDATA instruction cannot be executed. Channel %3 is
not active
%1 = Channel number
%2 = Block number, label
%3 = String (CHANDATA parameter)
With a CHANDATA instruction, the data input for a channel is selected that has not been
activated. For structural reasons, the input of multi-channel data must take place twice.