Siemens SINUMERIK 840D Diagnostics Manual page 544

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
Reactions:
Remedy:
Program Continuation:
300400
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300401
Parameters:
1-544
- Mode group not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. You can try to power the sys-
tem up again. The search for the precise cause of error can only be performed by the
development team. The displayed status code is always needed for this.
(contact SIEMENS AG, System Support for A&D MC products, Hotline (Tel.: see alarm
1000).
Switch control OFF - ON.
Axis %1 drive %2 system error, error codes %3, %4
%1 = NC axis number
%2 = Drive number
%3 = Error code 1
%4 = Error code 2
An internal software error or serious error condition has occurred which may be recover-
able by hardware reset. Troubleshooting can generally be performed only by Siemens
AG, System Support for A&D MC Products, Hotline (tel.: see alarm 1000).
In the error code combination (324,26), the calculation time allocation for the drive com-
munication subtask should be increased via the MD 10140
$MN_TIME_LIMIT_NETTO_DRIVE_TASK (possible up to 500 ms).
If the above-mentioned limit is exhausted and the alarm continues to occur, the MD 10150
$MN_PREP_DRIVE_TASK_CYCLE_RATIO=1 can be set additionally. Please note that
by reducing MD 10150, the time share of the preparation in the non-cyclic time plane is
reduced. This may lead to longer block cycle times.
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Please inform the authorized personnel/service department. You can try to power the sys-
tem up again. The search for the precise cause of error can only be performed by the
development team. The displayed error codes are always needed for this.
(contact SIEMENS AG, System Support for A&D MC products, Hotline (Tel.: see alarm
1000).
Switch control OFF - ON.
Drive software for type %1, block %2 missing or incorrect
%1 = Drive type
%2 = Block number
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents