Siemens SINUMERIK 840D Diagnostics Manual page 128

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
10881
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10882
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10883
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-128
Channel %1 block %2 overflow of local block buffer when inserting chamfers or
radii
%1 = Channel number
%2 = Block number, label
Between 2 blocks containing the contour elements and to be joined with a chamfer or a
radius (CHF, RND), so many dummy blocks have been programmed without contour
information that the internal buffer is too small.
- Correction block is reorganized.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
Modify part program such that the number of dummy blocks is reduced.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 activation of chamfers or radii (non-modal) without travers-
ing movement in the block
%1 = Channel number
%2 = Block number, label
No chamfer or radius has been inserted between 2 linear or circle contours (edge break-
ing) because:
• There is no straight line or circle contour in the plane
• There is a movement outside of the plane
• A plane change has taken place
• The permissible number of dummy blocks without traversing information has been
exceeded.
- Correction block is reorganized.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Correct the part program
according to the above error description or change the number of dummy blocks in the
channel-specific MD CHFRND_MAXNUM_DUMMY_BLOCKS to comply with the maxi-
mum number allowed for in the program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 chamfer or fillet has to be reduced
%1 = Channel number
%2 = Block number, label
This alarm is output, if at least one of the relevant blocks when inserting chamfers or radii
is so short, that the contour element to be inserted must be reduced against its originally
programmed value. The alarm occurs only if bit 4 is set in the machine data
$MN_ENABLE_ALARM_MASK. Otherwise, the chamfer or radius is adapted without an
alarm being output.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm at block end.
Modify NC program of continue program without modifications after CANCEL and Start or
with Start alone.
Clear alarm with the Delete key or NC START.
 Siemens AG, 2004. All rights reserved