1 Alarms
Reactions:
Remedy:
Program Continuation:
4160
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4170
Definitions:
Reactions:
Remedy:
Program Continuation:
4180
Definitions:
1-46
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Configure block length/display range within the permissible limits.
Switch control OFF - ON.
Channel %1 invalid M function number configured for spindle switchover
%1 = Channel number
An M function was specified in machine data $MC_SPIND_RIGID_TAPPING_M_NR in
order to configure the M function number for spindle switchover. The M function number is
assigned by the system and cannot be used for the switchover (M1 to M5, M17, M30,
M40 to M45).
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
(M1 to M5, M17, M30, M40 to M45). Configure an M function which is not used by the sys-
tem (M1 to M5, M17, M30, M40 to M45) in machine data
$MC_SPIND_RIGID_TAPPING_M_NR.
Switch control OFF - ON.
Invalid M function number for channel synchronisation assigned
An M number between 0 and 99 has been specified In machine data
$MN_EXTERN_CHAN_SYNC_M_NR_MIN or
$MN_EXTERN_CHAN_SYNC_M_NR_MAX for the configuration of the M number range
for channel synchronization in ISO2/3 mode or the machine data
$MN_EXTERN_CHAN_SYNC_M_NR_MAX is smaller than
$MN_EXTERN_CHAN_SYNC_M_NR_MIN.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Check machine data $MN_EXTERN_CHAN_SYNC_M_NR_MIN and
$MN_EXTERN_CHAN_SYNC_M_NR_MAX.
Switch control OFF - ON.
Invalid M function number assigned to enable ASUP
An invalid M function number has been assigned for activation of ASUP. An illegal M
number has been assigned in machine data $MN_EXTERN_M_NO_SET_INT or
$MN_EXTERN_M_NO_DISABLE_INT for the configuration of the M number range for
activation/deactivation of the interrupt program.