10.04
Definitions:
Reactions:
Remedy:
Program Continuation:
17090
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
17095
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
17100
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
An attempt was made to write a machine data with a value that is smaller than the defined
lower limit.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Determine the input limits of
the machine data and assign a value within these limits.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 %3 value exceeds upper limit
%1 = Channel number
%2 = Block number, label
%3 = MD
An attempt was made to write a machine data with a value that is greater than the defined
upper limit.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Determine the input limits of
the machine data and assign a value within these limits.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 invalid value
%1 = Channel number
%2 = Block number, label
An attempt was made to write an invalid value, e.g. zero, into a machine data.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Correct the value assignment, e.g. a value within the value range not equal to zero.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 digital input/comparator no. %3 not activated
%1 = Channel number
%2 = Block number, label
%3 = Input number
Either an attempt was made to read a digital input n via the system variable $A_IN[n] and
this input has not been activated via NCK machine data 10350
FASTIO_DIG_NUM_INPUTS; or to read a comparator input via system variable
$A_INCO[n] and this input belongs to a comparator which has not been activated.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Modify part program or
machine data accordingly.
Clear alarm with NC START or RESET key and continue the program.