Siemens SINUMERIK 840D Diagnostics Manual page 580

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
300739
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300740
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300741
Parameters:
Definitions:
Reactions:
1-580
Axis %1 drive %2 measuring system already used as motor measuring system
%1 = NC axis number
%2 = Drive number
The NC has assigned the direct measuring system to a measuring system output which is
already used by another motor measuring system. This error can only occur with the
810D!
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Check the configuration of
the direct measuring system. See NC-MD 30220: $MA_ENC_MODULE_NR and NC-MD
30230: $MA_ENC_INPUT_NR.
Switch control OFF - ON.
Axis %1 drive %2 measuring system used several times
%1 = NC axis number
%2 = Drive number
The NC has assigned the direct measuring system to a measuring system output which is
already used by another direct measuring system. This error can only occur with the
810D!
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Check the configuration of
the direct measuring system. See NC-MD 30220: $MA_ENC_MODULE_NR and NC-MD
30230: $MA_ENC_INPUT_NR.
Switch control OFF - ON.
Axis %1 drive %2 asynchronous mode: feedforward control gain out of range
%1 = NC axis number
%2 = Drive number
If motor inertia and motor nominal torque have been selected unfavorably, the asynchro-
nous motor feedforward control gain is beyond the range of the internal number format.
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
 Siemens AG, 2004. All rights reserved