Siemens SINUMERIK 840D Diagnostics Manual page 323

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Reactions:
Remedy:
Program Continuation:
20091
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20092
Parameters:
Definitions:
Reactions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Please inform the authorized personnel/service department.
• Check the axis type.
• Check MD 37000.
• Is a machine axis movement missing in the approach block?
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Axis %1 has not reached fixed stop
%1 = Axis name, spindle number
On attempting to traverse against a fixed stop, the programmed end position has been
reached or the traversing movement has been aborted. The alarm can be concealed by
means of the machine data $MA_FIXED_STOP_ALARM_MASK.
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY
(channel not ready).
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Correct the part program and the settings:
• Has the traversing block been aborted?
• If the axis position does not correspond to the programmed end position, then correct
the end position.
• If the programmed end position is in the part, the triggering criterion must be checked.
• Has the contour deviation leading to triggering been dimensioned too large? Has the
torque limit been set too high?
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Axis %1 travel to fixed stop still active
%1 = Axis name, spindle number
An attempt has been made to move an axis while it is in fixed stop or while the deselec-
tion function has not yet been completed.
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY
(channel not ready).
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
1 Alarms
1-323