10.04
Remedy:
Program Continuation:
7200
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
7201
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
7202
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
7205
Parameters:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Please inform the authorized personnel/service department. Set the machine data for
dividing up the VDI user interface of the compile cycles (DB 9) into input and output bytes
in accordance with the functions in the compile cycles. The maximum quantity of 400
bytes must not be exceeded. There are no restrictions concerning the division into input
and output bytes.
Switch control OFF - ON.
Problem with externally linked compile cycle %1 %2
%1 = Internal number
%2 = could be
Problem with externally linked compile cycles.
- Alarm display.
See function description of the compile cycle!
Clear alarm with the Delete key or NC START.
Assertion error in %1 line %2
%1 = String (path with program name)
%2 = String (line number)
This alarm is purely a development alarm. It only occurs with externally linked compile
cycles.
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Alarm reaction delay is canceled.
Consultation with CC developer
Clear alarm with the RESET key in all channels. Restart part program.
Missing option bit for %1: %2 <hex>
%1 = (string) name of the specific .elf file
%2 = (int) required option bit (hex)
Alarm for SIEMENS compile cycles. This alarm appears when the option bit required for a
SIEMENS compile cycle is not set.
- NC not ready.
- Channel not ready.
- Interface signals are set.
- Alarm display.
- Alarm reaction delay is canceled.
Set the required option bit or delete the .elf file from the Flash File System.
Clear alarm with the RESET key in all channels. Restart part program.
Incompatible OEM transformation channel %1 version NCK %2 CC %3
%1 = (int) channel number
%2 = Transformer interface version NCK
%3 = Transformer interface version OEM
1 Alarms