10.04
16933
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16934
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16935
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16936
Parameters:
Definitions:
Reactions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Channel %1 interrupt treatment: action %2<ALNX> not allowed in the current state
%1 = Channel ID
%2 = Action number/action name
If a temporary standstill has occurred because of a Reorg event across block boundaries,
it is possible that a block without Reorg capability has been loaded. In this situation, it is
unfortunately necessary to abort the Reorg event handling! Reorg events are, e.g. abort
subprogram, delete distance-to-go and interrupts.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Abort program with the RESET key.
Clear alarm with the RESET key. Restart part program
Channel %1 interrupt treatment: action %2<ALNX> not possible due to stop
%1 = Channel ID
%2 = Action number/action name
Reorg events are, e.g. abort subprogram, delete distance to go and interrupts, axis
replacement, termination of follow-up mode. Two Reorg events overlap in this situation.
The 2nd Reorg event coincides with the 1st block generated by the previous event. (e.g.
an axis replacement is induced twice in rapid succession). Axis replacement leads to
Reorg in the channels in which an axis is removed without preparation. This block must
be stopped in the above sequence in order to prevent the interpolator buffer from over-
flowing. This can be achieved by pressing the Stop or StopAll key, configuring an alarm
with INTERPRETERSTOP or by decode single block.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
The program must be aborted with Reset.
Clear alarm with the RESET key. Restart part program
Channel %1 action %2<ALNX> not possible due to search run
%1 = Channel ID
%2 = Action number/action name
The action is not allowed as block search is currently running via program test. Block
search via program test: "PI Service _N_FINDBL with mode parameter 5_.
With this block search type, it is not permissible to activate program test or dry run fee-
drate.
- Alarm display.
Activate the action after block search is terminated.
Clear alarm with the Delete key or NC START.
Channel %1 action %2<ALNX> not possible due to active dry run
%1 = Channel ID
%2 = Action number/action name
This action is not allowed as dry run feedrate is currently active.
Example: It is not permissible to activate block search via program test (PI service
_N_FINDBL with mode parameter 5) when dry run feedrate is active.
- Alarm display.
1 Alarms
1-275