Siemens SINUMERIK 840D Diagnostics Manual page 317

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Reactions:
Remedy:
Program Continuation:
20059
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20060
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20061
Parameters:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- Alarm display.
The reference axis/spindle must be modified accordingly in SD 43300.
Alarm display showing cause of alarm disappears. No further operator action necessary.
Channel %1 axis %2 already active due to %3
%1 = Channel number
%2 = Axis name, spindle number
%3 = Cause
The axis (machine axis, geometry axis or orientation axis) is to be traversed in operation
mode "Automatic&Jog" (see $MN_JOG_MODE_MASK) by using the direction keys or a
handwheel. This is not possible, as (see parameter 3):
1. the axis is active as a rotating spindle
2. the axis is a PLC axis
3. the axis is active as an asynchronous reciprocating axis
4. the axis is active as a command axis
5. the axis is active as a slave axis
6. a frame applies for a rotated coordinate system and an axis involved in the required
JOG movement of the geometry axis is not available for this
7. an axis container rotation is activated via NCU link
Note: This alarm identifies an axis not capable of JOG which received a JOG order. In this
case, the NCK will not proceed according to "Internal JOG".
- Alarm display.
Wait for the axis to traverse or abort with distance-to-go delete or RESET.
Clear alarm with the Delete key or NC START.
Channel %1 axis %2 cannot be traversed as geometry axis
%1 = Channel number
%2 = Axis name
The axis is currently not in "Geometry axis" state. Therefore, it cannot be traversed in
JOG mode as geometry axis.
If the abbreviation WCS (workpiece coordinate system) is displayed in the "Position"
screen, then only the geometry axes can be traversed by means of the direction keys!
(MCS ... Machine coordinate system; all machine axes can now be traversed by using the
direction keys on the machine control panel).
- Alarm display.
Check the operating steps to establish whether geometry axes really must be traversed,
otherwise switch over to the machine axes by activating the "WCS/MCS" key on the
machine control panel.
Clear alarm with the Delete key or NC START.
Channel %1 axis %2 cannot be traversed as orientation axis
%1 = Channel number
%2 = Axis name
1 Alarms