10.04
12475
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12480
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12490
Parameters:
Definitions:
Reactions:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Channel %1 block %2 invalid G function number %3 programmed
%1 = Channel number
%2 = Block number, label
%3 = G code number
A non-allowed G function number (parameter 3) has been programmed for a G group with
indirect G code programming. Only the G function numbers indicated in the Programming
Guide "Fundamentals", Section 12.3 "List of G functions/Path conditions" are allowed.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 subroutine %3 already defined
%1 = Channel number
%2 = Block number, label
%3 = Source string
The name used in the PROC or EXTERN instruction has already been defined in another
call description (e.g. for cycles).
Example:
EXTERN CYCLE85 (VAR TYP1, VAR TYP2, ...)
- Correction block
- Interface signals are set.
- Alarm display.
Press the NC Stop key and select the function "Correction block" with the softkey PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block. A program
name must be selected that has not yet been used as identifier. (Theoretically, the param-
eter declaration of the EXTERN instruction could also be adapted to the existing subrou-
tine in order to avoid the alarm output. However, it would have been defined identically
twice).
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 access permission level %3 is not valid
%1 = Channel number
%2 = Block number, label
%3 = Source string
The desired access authorization, programmed with the keyword REDEF, has not been
set. The desired protection level is either beyond the permitted value range or the protec-
tion level change is not allowed.
(The REDEF instruction is only executable in INITIAL_INI blocks on SINUMERIK 840D,
P1 (6/94)).
The protection level may be changed only if:
1. The current protection level is equal to or higher than the level originally defined, and
2. The new protection level is to be below the level originally defined.
The higher numerical values represent the lower protection levels. The lower 4 levels
(from 7 to 4) correspond to the keyswitch positions, and the upper 4 levels are associated
with 4 passwords.
- Correction block
- Interface signals are set.
- Alarm display.
1 Alarms
1-157