1 Alarms
1-384
4: No cross-comparison.
5: Function enables. Enter equal MDs.
6: Limit value for SG1. Enter equal MDs.
7: Limit value for SG2. Enter equal MDs.
8: Limit value for SG3. Enter equal MDs.
9: Limit value for SG4. Enter equal MDs.
10: Standstill tolerance. Enter equal MDs.
11: Upper limit value SE1. Enter equal MDs.
12: Lower limit value SE1. Enter equal MDs.
13: Upper limit value SE2. Enter equal MDs.
14: Lower limit value SE2. Enter equal MDs.
15: Safe cam 1+ (+tolerance). Enter equal MDs.
16: Safe cam 1+. Enter equal MDs.
17: Safe cam 1- (+tolerance). Enter equal MDs.
18: Safe cam 1-. Enter equal MDs.
19: Safe cam 2+ (+tolerance). Enter equal MDs.
20: Safe cam 2+. Enter equal MDs.
21: Safe cam 2- (+tolerance). Enter equal MDs.
22: Safe cam 2-. Enter equal MDs.
23: Safe cam 3+ (+tolerance). Enter equal MDs.
24: Safe cam 3+. Enter equal MDs.
25: Safe cam 3- (+tolerance). Enter equal MDs.
26: Safe cam 3-. Enter equal MDs.
27: Safe cam 4+ (+tolerance). Enter equal MDs.
28: Safe cam 4+. Enter equal MDs.
29: Safe cam 4- (+tolerance). Enter equal MDs.
30: Safe cam 4-. Enter equal MDs.
31: Position tolerance. Enter equal MDs.
32: Reference position tolerance. Enter equal MDs.
33: Time velocity changeover. Enter equal MDs.
34: Tolerance time SGE changeover. Enter equal MDs.
35: Delay time pulse deletion. Enter equal MDs.
36: Time for check of pulse deletion. Enter equal MDs.
37: Transition time STOP C to SBH. Enter equal MDs.
38: Transition time STOP D to SBH. Enter equal MDs.
39: Transition time STOP E to SBH. Enter equal MDs.
40: Stop reaction to SG. Enter equal MDs.
41: Stop reaction to SE. Enter equal MDs.
42: Creep speed pulse deletion. Enter equal MDs.
43: Storage test stop reaction.
44: Actual position value + limit value SG1.
45: Actual position value - limit value SG1.
46: Actual position value + limit value SG2.
47: Actual position value - limit value SG2.
48: Actual position value + limit value SG3.
49: Actual position value - limit value SG3.
50: Actual position value + limit value SG4.
51: Actual position value - limit value SG4.
52: Standstill position + tolerance.
53: Standstill position - tolerance.