Siemens SINUMERIK 840D Diagnostics Manual page 175

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Reactions:
Remedy:
Program Continuation:
14013
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14014
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14015
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14016
Parameters:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Modify the machining program so that the nesting depth is reduced, e.g. using the editor
copy a subroutine of the next nesting level into the calling program and remove the call for
this subroutine. This reduces the nesting depth by one program level.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 number of subroutine passes invalid
%1 = Channel number
%2 = Block number, label
In a subroutine call the programmed number of passes P is zero or negative.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Program number of passes between 1 and 9 999.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 selected program %3 not available or will be edited
%1 = Channel number
%2 = Block number, label
%3 = Program name
The selected parts program is not in the NCK memory or the access authorization for the
program selection is from a higher level than the current control status.
During creation, this program received the protection level of the NC control which was
active at the time.
In SW 5 or higher a program edited on HMI can no longer be started with NC Start.
The alarm will also be issued, if a file other than the specified definition file has been
selected for the GUD or macro definition.
- Alarm display.
Reload the program in the NCK memory or check and correct the name of the directory
(workpiece overview) and the program (program overview) and reselect.
Clear alarm with the Delete key or NC START.
Channel %1 block %2 program %3 is not enabled
%1 = Channel number
%2 = Block number, label
%3 = Program name
The user has no execution authorization for the file, the file is not released.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Change user authorization,
release file.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 error when calling the subroutine via M/T function
%1 = Channel number
%2 = Block number, label
1 Alarms