Siemens SINUMERIK 840D Diagnostics Manual page 485

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
75500
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
75600
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
75601
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Channel %1 HSLC: Wrong configuration
%1 = Channel number
Technology function "rapid cycle-independent switching with 2D path relation" has not
been parameterized correctly. There are two reasons for this alarm:
• No geometry axis has been defined
• The option "Software cam" is set.
- Alarm display.
- NC Stop on alarm.
Modify MD configuration.
Clear alarm with the RESET key. Restart part program
Channel %1 RESU: wrong MD configuration. Error code %2
%1 = Channel number
%2 = Error code
The following errors were detected in the machine data of the retrace support function
when ramping up:
Error code = 4 : Machine date $MC_MM_NUM_CC_BLOCK_ELEMENTS or
$MC_MM_NUM_CC_BLOCK_USER_MEM must be increased.
Error code = 5 : Insufficient heap memory for compile cycles available. Adjust machine
data $MC_RESU_RING_BUFFER_SIZE, $MC_RESU_SHARE_OF_CC_HEAP_MEM
and $MC_MM_NUM_CC_HEAP_MEM.
Error code = 6 : The machine data $MN_ASUP_START_MASK and
$MN_ASUP_START_PRIO_LEVEL are not set correctly.
Error code = 11: Machine data $MC_AXCONF_GEOAX_NAME_TAB[n],
$MN_INTERMEDIATE_POINT_NAME_TAB[n] and $MN_IPO_PARAM_NAME_TAB[n]
are not set correctly for RESU:
Error code = 13: With bit 2 = 0 of MD $MC_RESU_SPECIAL_FEATURE_MASK it was
specified that the retraction program cc_resu.mpf is to be stored in the DRAM parts pro-
gram memory. However, no DRAM parts program memory was requested via MD
$MN_MM_DRAM_FILE_MEM_SIZE. Remedy: Either set MD
$MN_MM_DRAM_FILE_MEM_SIZE to a value unequal to zero or set bit 2 of MD
$MC_RESU_SPECIAL_FEATURE_MASK equal to one.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Correct machine data.
Switch control OFF - ON.
Channel %1 block %2 invalid parameter in CC_PREPRE()
%1 = Channel number
%2 = Block number, label
Only the values _1, 0, 1 are valid parameters for CC_STOPRE().
- Interpreter stop
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with the RESET key. Restart part program
1 Alarms
1-485

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents