1 Alarms
Definitions:
Reactions:
Remedy:
Program Continuation:
4340
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4341
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4342
Parameters:
1-56
The parameters of the orientation transformation are taken over from the data of an ori-
entable toolholder. This orientable toolholder contains an invalid transformation type.
(Types T, P and M are permissible).
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm at block end.
Enter a valid transformation type.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 invalid transformation type in transformation no. %3
%1 = Channel number
%2 = Block number, label
%3 = Transformation number
An invalid, i.e. undefined, number was entered in one of the machine data
TRAFO_TYPE_1 ... TRAFO_TYPE_8. This alarm also occurs if a certain type of transfor-
mation is only impossible on the type of control used (e.g. 5-axis transformation on a
SINUMERIK 802D).
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm at block end.
Enter a valid transformation type.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 no data set available for transformation no. %3
%1 = Channel number
%2 = Block number, label
%3 = Transformation number
Only a limited number of machine data sets (usually 2) is available for each related group
of transformations (e.g. orientation transformations, Transmit, Tracyl, etc.). This alarm is
output if an attempt is made to set more transformations from a group.
Example:
Two orientation transformations are allowed. The machine data contains e.g.:
TRAFO_TYPE_1 = 16 ; 1st orientation transformation
TRAFO_TYPE_2 = 33 ; 2nd orientation transformation
TRAFO_TYPE_3 = 256 ; 1st transmit transformation
TRAFO_TYPE_4 = 20 ; 3rd orientation transformation ==> This entry triggers alarm
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm at block end.
Enter valid machine data.
Clear alarm with the RESET key. Restart part program.
Channel %1 invalid machine data for general 5-axis transformation error no. %2
%1 = Channel number
%2 = Error type